Vedere la pagina 59
Installation and User Manual ADPRO FastTrace-R by Xtralis
48 Doc 13972_03
Figure 53: Pin Numbering of the Data Port
Table 10: Data Port Connections
3.12 Connecting to the General I/O
General Inputs/Outputs are available via screw connection strips on the rear panel.
Figure 54: Pinouts for General I/O Connector
3.12.1 Export Evidence - Pin 1
Currently not used.
3.12.2 Access/Secure Input - Pin 3
Not used in FastTrace-R operation.
PIN Signal Description
1 DCD Carrier Detect
2 RXD Receive Data
3TXDTransmit Data
4 DTR Data Terminal Ready
5 GND Signal Ground
6 DSR Data Set Ready
7 RTS Request to send
8 CTS Clear to send
9 +V Signal High
EE
A/S
CLK
PTT
MOD SEL
FLT COM
FLT NO
FLT NC
P73 general io pinouts.cdr
123 45678 9101112131415
GND
GND
GND
GND
Pins 1-15
15-pin Screw Terminal Connector
ALM COM
ALM NO
ALM NC