Installation
ADPRO FastTrace, Issue 5 1 - 17
The setup options for Alarm Inputs are described with reference to the ‘rest’ or non-alarm position of a set of switch
contacts:
Normally Open - needs a closing alarm contact to activate an alarm
Normally Closed - needs an opening alarm contact to activate an alarm
SEOL Normally Open - Single End of Line termination with N/O contacts
SEOL Normally Closed - Single End of Line termination with N/C contacts
DEOL Normally Open - Dual End of Line termination with N/O contacts
DEOL Normally Open - Dual End of Line termination with N/C contacts
WARNING
DO NOT attempt to solder directly onto the connector pins, as this may cause heat damage
to the connector housing or to the interface PCB.
Vedere la pagina 27